Adapter: SAE J1772(Type 1); IEC62196-2(Type 2)
Output Rating :1phase 16A 3.5kw, 1phase 32A 7kw, 1phase 40A 10kw
Communication: WIFI, LAN(RJ-45),RS-485,OCPP 1.6J
Certification:CE, ROHS, REACH, cULus. FCC
RCD Type B
APP Control:
● Setting Current
● Controlling Stop & Start
● Making an Appointment of Charging
Load Balance Management:Eliminate a Risk of Overloading
M3P U-Series |
Specification | US Standard | EU Standard |
Charging Connector Type | SAE J1772 (Type 1) | IEC 62196-2 (Type 2) |
AC Power Input Rating | AC Level 2, 240V | 230V±15% |
Frequency Rating | 50/60 Hz |
AC Power Output Rating | 3.5kw/16A |
7kw/32A |
10kw/40A (US Standard optional) |
RCD | Type B |
Environmental |
Storage Temperature | -40 ~ 75℃ | Operating Temperature | -30 ~ 55℃ |
Operating Humidity | Up tp 95%, non-condensing | Altitude | ≤2000m |
Cooling Method | Natural Cooling |
M3P Wallbox Mechanical |
IP Code | IP65 | Dimension(H×W×D,mm) | 310×220×95 |
Weight | 7kg | Charging Cable Length | 5m or Customized |
Enclosure Material | PC |
|
|
User Interface & Control |
|
|
|
Wifi | Yes | Plug-and-Charging | Yes |
RFID Card Charging | Yes | App Charging | Yes |
Ethernet Interface | Yes | Wifi Function | Yes |
OCPP Protocol | OCPP 1.6 | Load Balance | Optional |
Protection |
Over Voltage Protection | Yes | Under Voltage Protection | Yes |
Over Load Protection | Yes | Short Circuit Protection | Yes |
Earth Leakage Protection | Yes | Ground Protection | Yes |
Over-temp Protection | Yes | Surge Protection | Yes |
RCD | Type B |
Advantages:
 |
| 1. APP Control ● Setting Current: you can set the current when the power grid is overload. ● Controlling Stop & Start: Control the Stop &Start by your phone, you can control it in anywhere. ● Booking of Charging:If you want the electric vehicle to be charged in night, it is a good choice that you make an appointment of the charging by APP, it is very convenient. ● Record: you can check the charging record by APP in any time. ● The best Choice for home market. |
2. Load balance management: ● Restricting the total charging load protects the local grid ● Sharing the charging load cuts costs for the required electricity connection ● Choose an open type CT (current transformer) as the current sensor, It is no physical wiring between the devices, which has the advantage of open and close installation, convenient and fast wiring,no extra infrastructure or installation costs. |
|  |
 |
| 3. Specification ● OEM or ODM Available:Logo, brand, design, size, color, function, etc,customization available; ● IP 65:Indoor and outdoor applications with waterproof IP65 rated ● Versatile Installation wall mount or pedestal applications ● Communication: WIFI, LAN(RJ-45),RS-485,OCPP 1.6J |
4. Protection: ● RCD TypeB inside. ● High quality production and design standards for safe and reliable use with multiple fault protection: Overvoltage Protection, Undervoltage Protection, Overload Protection, Short Circuit Protection, Earth leakage Protection, Ground Protection, Over-tempProtection, Surge Protection and etc. |
|  |